半导体压电阻抗扩散压力传感器是在薄片表面形成半导体变形压力,通过外力(压力)使薄片变形而产生压电阻抗效果,新型压差传感器楼梯间,从而使阻抗的变化转换成电信号。
静电容量型压力传感器,是将玻璃的固定极和硅的可动极相对而形成电容,将通过外力(压力)使可动极变形所产生的静电容量的变化转换成电气信号。 (E8Y的动作原理便是静电容量方式,其他机种采用半导体方式)。





前室压力探测器前室微压差压力传感器
When the supply air volume and time of itive pressure air supply system is out of control, the normal escape route may be too high because of the itive pressure of the front room, the fire door can not open the serious cequences. In view of the above ciderati,前室微压差压力传感器价格, the Sichuan Institute of Fire Science combined with experience to provide data of residual pressure value. By controlling the opening and closing of the by-pass Valve,前室微压差压力传感器, the differential control system can effectively control the residual pressure of the mechanical pressurized air supply system within the reasonable range required by the national standard ——40-50 PA in the ***oke-proof Stairwell,前室微压差压力传感器供应商, the front room, the shared front room,前室微压差压力传感器厂家, the front room of the fire elevator room and the enclosed refuge floor (room) are 25-30Pa.






通用型压差控制器广泛应用于前室(合用前室)压差测控系统、封闭避难层、防烟楼梯间压差测控系统;室内外压差检测、过滤网堵塞监控系统等干燥气体的压差测控系统。
特点:
◆带一个绿色巡检指示灯,一个红色报警指示灯;◆直接输出开关控制信号;◆供电及信号输出采用总线制传输;
产品参数:
量 程:0~100Pa 控制器寿命: 10万次
耐 压:1000Pa 电气等级: 24 VDC/0.3A
动作压力: 切 换 率: 大6次/分钟
前室/走道:25~30Pa,(复位压力:15~20Pa); 外形尺寸:172*112*60






前室微压差压力传感器-紫旭空调没有中间商由武城县豪鲁邦空调设备有限公司提供。武城县豪鲁邦空调设备有限公司实力不俗,信誉可靠,在山东 德州 的继电器等行业积累了大批忠诚的客户。豪鲁邦空调带着精益求精的工作态度和不断的完善创新理念和您携手步入辉煌,共创美好未来!