Guardian 6000 Plus Electrical Safety Analyzer
The Guardian 6000 Plus is able to perform several dielectric tests in one unit including AC/DC Hipot, Insulation Resistance,Ground Bond, Open/Short Check and optional Leakage Current for compliance testing of IEC, UL, TUV, CSA, EN and other standa*** including IEC60601-1, UL2601-1, IEC950, UL544, UL60950. The time-s***ing TwinPort™ featureperforms Hipot and Ground Bond simultaneously cutting time for these tests in half. The open / short check function (OSC)checks for an open connection or a DUT short during testing. Open connecti*** may cause a bad DUT to test OK. Screening for shorts prevents damage to the equipment s***ing potential costs that may occur. These patented features are only ***ailable in safety products manufactured by Chroma.
>>> See Specs
EST Software
EST software controls the analyzer to perform electrical safety integrated tests from the PC. The EST software allows you to s***e test procedures and data directly as well as exporting the data EXCEL files for quick management reporting and statistical analysis.
|
|
- Program edit and GO/NG control
- Data bank
- Report function
- Statistical analysis function
- Authority management function
|
Ordering information
|
Guardian 6000 Plus: Electrical Safety Analyzer
A190301: 8HV Scanning Box
A190302: 5HV/3GC Scanner
A190303: 3HV/5GC Scanner
A190304: 8HV Scanner
A190305: Line Leakage Current Scanner
A190306: Hipot/Line Leakage/Probe Scanner (10A)
A190307: L-N Scanner & Leakage Current Scanner
A190308: Hipot/Line Leakage/Probe Scanner (20A)
A190313: 500VA Isolation Transformer
A190314: 1000VA Isolation Transformer
|
A190316: Dummy Load
A190317: Bar Code Scanner
A190321: GPIB Interface
A190334: Ground Bond 40A
A190337: Ground Bond 60A
A190338: 19001 EST Software
A190309: EMI FILTER Scanner
A190342: EMI FILTER Test Box
A190343: 19" Rack Mount Kit for Model 19032
A190344: HV Gun
A190349: Universal Corded Product Adapter
A190708: ARC Verification Fixture
|
Specificati***
| Guardian 6000 Plus |
| Mode |
AC / DC / IR / GB / LC |
| Withstanding Voltage Test |
| Output Voltage |
DC:0.05 ~ 6kV , AC : 0.05 ~ 5kV |
| Load Regulation |
&plu***n;(1% of reading +0.1% of range) |
| Voltage Regulation |
2V |
| Voltage Accuracy |
&plu***n;(1% of reading +0.1% of range) |
| Cutoff Current |
DC : 20mA , AC : 40mA |
| Current Resolution |
0.1 μA DC |
| Current Accuracy |
&plu***n;(1% of reading +0.1% of range) |
| Output Frequency |
50Hz / 60Hz |
| Test Time |
0.3 ~ 999 sec , continue |
| Ramp Time |
0.1 ~ 99.9 sec, Off |
| Fall Time |
0.1 ~ 99.9 sec, Off |
| W***eform |
Sine w***e |
| Insulation Resistance Test |
| Output Voltage |
DC : 0.05 ~ 1kV |
| Voltage Resolution |
2V |
| Voltage Accuracy |
&plu***n;(2% of reading +0.5% of range) |
| IR Range |
1MΩ ~ 50GΩ |
| Resistance Resolution |
0.1MΩ |
| Resistance Accuracy |
5% typical |
| Ground Bond Test |
| Output Current |
AC : 1 ~ 30A (40A, 60A optional) |
| Current Accuracy |
&plu***n;(1% of reading +0.2% of range) |
| GR Range |
10mΩ ~ 510mΩ |
| Resistance Resolution |
0.1mΩ |
| Resistance Accuracy |
&plu***n; (1% of reading + 0.1% of full scale) |
| Test Method |
4 wires |
| Flashover Detection |
| Setting Mode |
Programmable setting |
| Detection Current |
AC : 20mA, DC : 10mA |
| Secure Protection Function |
| Panel Operation Lock |
Present password |
| Interlock |
YES |
| GO/NG Judgment Window |
| Indication,Alarm |
GO: Short sound,Green LED; NG: Long sound, Red LED |
| Data Hold |
Least tests data memories |
| Memory Storage |
50 setups with up to 100 groups recall |
| Interface |
| 9pin D-sub I/O control / RS232 / GPIB (Optional) |
| General |
| Operation Environment |
Temperature : 0°C ~ 40°C, Humidity : &plu***n; 80 % RH |
| Power C***umption |
No load : < 100 W With rated load : 800 W |
| Power Requirements |
90~132Vac or 198~264Vac, 47~66Hz |
| Weight |
Approx. 20KG(19032) 25KG (19032-P) |
|