Simpson228 AC/DC Leakage Current Tester
True RMS Readings
Reads in Measurement Indication Units (MIU) up to .005 MIU
Output Allows Measurement of Peak Current in Non-Sinusoidal Wave Forms
Let-Go, Reaction, and Burn Hazard Response Networks
Burn Hazard Network
Incorporates 3-Special Networks Required by Guidelines
Detects Dangerous AC & DC Leakage Currents
|
Equivalent measuring instrument load |
|
|
Reaction Response Network |
1 MΩ - 10pF |
|
Let-Go Response Network |
1 MΩ - 62pF |
|
Unweighted Burn Hazard Response Network |
1 MΩ - 1pF |
|
Ranges |
|
|
Reaction Response Network |
.3, 1, 3, 10 M.I.U. |
|
Let-Go Response Network |
.3, 1, 3, 10 M.I.U. |
|
Unweighted Burn Hazard Response Network |
0-100 mA RMS |
|
Meter accuracy |
±2% F.S. @ 60 Hz |
|
Meter frequency response |
|
|
DC to 1 Hz |
Pointer shall track within 5% of peak |
|
15 Hz to 200 KHz |
%plusmn;2% of F.S. |
|
200 KHz to 1 MHz |
±2% F.S., ±2% F.S., ±5%F.S. |
|
Output |
|
|
Sensitivity |
Full scale meter indication equals 1Ω RMS (Measured with a 1 MV, 12 pF load) |
|
Accuracy |
±2% of reading @ 60 Hz |
|
Output frequency response |
|
|
Type |
0.52" (13.2mm) Diameter Electret Condenser, Omnidirectional 70° angle of incidence. Maximum sound pressure level 148dB |
|
Display |
|
|
DC to 1Hz |
±2% of reading |
|
50 Hz to 100 KHz |
±2.5% of reading, +2%/-3% of reading, ±2% of reading |
|
100 kHz to 1 MHz |
±5% of reading |
|
Voltmeter |
|
|
Range |
0-300 V (AC or DC) |
|
Accuracy: DC to 1 Hz |
Pointer shall track within 5% of peak |
|
Accuracy: 20 Hz to 1KHz |
±3% F.S. @ 60 Hz |
|
Frequency response |
DC to 1 KHz |
|
General |
|
|
Power requirements |
(2) 9V (NEDA 1604A) batteries |
|
Physical |
7" x 5.25" x 3", 2-1/2 lbs (1.4kg), ABS plastic, fused input |
|
Environmental |
27°C ±2°C, 70% noncondensing relative humidity. Outside this range derate by 10% per °C |
|
Maximum operating range |
0° to 40° C |