- According to DIN VDE 0816
- Temperature range
flexible -20°C to +50°C
fixed installation to +70°C
- Loop resistance at 20°C
0,6 mm = max. 130 Ohm/km
0,8 mm = max. 73,2 Ohm/km
- Operating voltage (peak voltage)
max. 225 V
- Test voltage
conductor/conductor U eff. 500²)
conductor/shield U eff. 2000 V
- Insulation resistance
min. 5 GOhm x km
|
- Line attenuation
of side circuits at 800 Hz
0,6 mm = 1,04 dB/km
0,8 mm = 0,78 dB/km
- Impedance
of side circuits at 800 Hz
0,6 mm = 720 Ohm
0,8 mm = 520 Ohm
- Minimum bending radius
approx. 10x cable Ø
- Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
- Caloric load values
see Technical Information
|
|
|
|
|
|
|
Part-No. |
Description & No. of Pairs x Diameter in mm |
Outer Ø (mm) |
Cop. weight
kg/km |
Weight
kg/km |
AWG |
34100 |
A-2Y (L) 2Y 2X2X0,6 |
8.0 |
11.0 |
82.0 |
- |
34101 |
A-2Y (L) 2Y 4X2X0,6 |
10.0 |
23.0 |
127.0 |
- |
34102 |
A-2Y (L) 2Y 6X2X0,6 |
11.5 |
34.0 |
132.0 |
- |
34103 |
A-2Y (L) 2Y 10X2X0,6 |
12.5 |
57.0 |
171.0 |
- |
34104 |
A-2Y (L) 2Y 20X2X0,6 |
15.5 |
113.0 |
268.0 |
- |
34105 |
A-2Y (L) 2Y 30X2X0,6 |
17.5 |
170.0 |
358.0 |
- |
34106 |
A-2Y (L) 2Y 40X2X0,6 |
19.5 |
226.0 |
438.0 |
- |
34107 |
A-2Y (L) 2Y 50X2X0,6 |
21.0 |
283.0 |
531.0 |
- |
34108 |
A-2Y (L) 2Y 70X2X0,6 |
24.5 |
396.0 |
712.0 |
- |
34109 |
A-2Y (L)2Y 100X2X0,6 |
28.0 |
565.0 |
950.0 |
- |
34110 |
A-2Y (L)2Y 150X2X0,6 |
33.0 |
848.0 |
1348.0 |
- |
34111 |
A-2Y(L)2Y 200X2X0,6 |
37.0 |
1131.0 |
1758.0 |
- |
34112 |
A-2Y(L)2Y 250X2X0,6 |
40.5 |
1414.0 |
2137.0 |
- |
34113 |
A-2Y (L)2Y 300X2X0,6 |
44.0 |
1696.0 |
2533.0 |
- |
34114 |
A-2Y (L)2Y 350X2X0,6 |
47.5 |
1979.0 |
2954.0 |
- |
34115 |
A-2Y (L)2Y 400X2X0,6 |
50.0 |
2262.0 |
3342.0 |
- |
34130 |
A-2Y(L)2Y 2X2X0,8 |
11.0 |
20.0 |
102.0 |
- |
34131 |
A-2Y(L)2Y 4X2X0,8 |
12.0 |
40.0 |
158.0 |
- |
34132 |
A-2Y(L)2Y 6X2X0,8 |
13.0 |
60.0 |
179.0 |
- |
34133 |
A-2Y(L)2Y 10X2X0,8 |
14.5 |
101.0 |
241.0 |
- |
34134 |
A-2Y(L)2Y 20X2X0,8 |
18.0 |
201.0 |
393.0 |
- |
34135 |
A-2Y(L)2Y 30X2X0,8 |
21.0 |
302.0 |
540.0 |
- |
34136 |
A-2Y(L)2Y 40X2X0,8 |
23.0 |
402.0 |
675.0 |
- |
34137 |
A-2Y(L)2Y 50X2X0,8 |
25.5 |
503.0 |
842.0 |
- |
34138 |
A-2Y(L)2Y 70X2X0,8 |
29.0 |
704.0 |
1105.0 |
- |
34139 |
A-2Y(L)2Y 100X2X0,8 |
34.0 |
1005.0 |
1524.0 |
- |
34140 |
A-2Y(L)2Y 150X2X0,8 |
40.0 |
1508.0 |
2208.0 |
- |
34141 |
A-2Y(L)2Y 200X2X0,8 |
46.5 |
2011.0 |
2915.0 |
- |
34142 |
A-2Y(L)2Y 250X2X0,8 |
51.0 |
2514.0 |
3575.0 |
- |
34143 |
A-2Y(L)2Y 300X2X0,8 |
53.0 |
3016.0 |
4232.0 |
- |
34144 |
A-2Y(L)2Y 350X2X0,8 |
56.5 |
3519.0 |
4940.0 |
- |
34145 |
A-2Y(L)2Y 400X2X0,8 |
60.0 |
4022.0 |
5565.0 |
- |
34146 |
A-2Y(L)2Y 500X2X0,8 |
68.0 |
5027.0 |
6955.0 |
- |
34147 |
A-2Y(L)2Y 600X2X0,8 |
73.0 |
6032.0 |
8240.0 |
- |
|
|
|
- Bare copper conductor, solid, 0,6 and 0,8 mmØ
- PE (2Y) conductor insulation, wall-thickness as per DIN VDE 0816 table 4
- Conductor identification of quads marked with black rings
- 4 conductors twisted to a star quad
- 5 star quads stranded to sub units,
each 5 or 10 sub units stranded to main units and the sub or main units stranded to cable conductor
- Conductor wrapping with several plastic tapes
- Outer jacket, as laminated jacket (L)2Y, PE-coated aluminum tape spliced with PE (2Y) jacket
- PE-outer jacket color black
- Jacket marking continuously with telephone-receiver, meter marking in white color
|
|
|
- These cables are not allowed for power installation
- For fire and hazardous areas, this cable type with PE-jacket is not permitted for installation without enough protective precaution
- Mutual capacitance at 800 Hz
of all values100%
0,6 mm - max. 52 nF/km
0,8 mm - max. 55 nF/km
of all values 95%
0,6 mm - max. 50¹) nF/km
0,8 mm - max. 53¹) nF/km
of all values 80%
0,6 mm - max. 48 nF/km
0,8 mm - max. 50 nF/km
- Capacitance unbalances at 800 Hz
of all values k1 100% - max. 800¹) pF/300 m
of all values k1 98% - max. 400 pF/300 m
of all values k9 - 12 100%-max. 300¹) pF/300 m
of all values k9 - 12 98% - max. 100 pF/300 m
|
|
|
- ¹) But at least for 2 quads.
- ²) Local cables with more than 100 pairs the test conductor/conductor is emitted.
- Conductor Ø 0,4 mm on request.
|
|
These external subscriber telephone cables are installed as telecommunication connection cable for connecting the telephone extension to the telephone exchange or central offices and as well as for industrial plants.
These subscriber connecting cables are suitable for laying in under ground, in cable ducts and cable conduits - and also for indoor-laying.
Both sides of PE-copolymer coated aluminum type (L), which is spliced with the outer PE-jacket ensures a barrier against water vapor and diagonally water-proof.
Black colored PE-jacket is UV-resistant.
The Polyethylene material (PE 2Y) is halogen-free.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. |
|
|
|