希而科优势代理德国Beluk GmbH PF-correction/measuring校正测量
PCF-relays
Power Factor Control Relay BLR-CX
Microprocessor controlled power factor controller with 1-phase measurement system

zoom | - Start menu for easy commissioning
- Automatic detection and correction of the phase of current and voltage connection
- Fully-automatic c/k-value setting, self adapting, connection of different capacitor step sizes possible
- Automatic detection and usage of the optimum capacitor step
- Switching programs: Best Fit, LIFO, manual mode, combifilter, progressive
- Capable for 4-quadrant operation
- 1-phase measurement system also suitable for non-sinusodial currents and voltages
- Supply voltage taken from measuring voltage
- Voltage measuring 90 – 550V, 45 – 65Hz
- Current measuring 15mA – 5A, suitable for CT x/1A und x/5A
- Connection with plugable screw terminals
- LCD with backlit
- Display of all important grid and system parameters
- Display of THD U and voltage harmonics from 3rd to 15th order
- Input for temperature sensor or thermostate (n/o)
(this input can be used to switch-over the tarif by n/o contact) - Alarm relay with voltfree n/o contact (operated at normal function)
- TTL-interface on rear
- Instrument casing for cutout 144 x 144mm, depth 49mm
- Protection class IP20 (casing), IP50 (front)
further information, optional parts and supplies(PDF; 120kb) |
 |
Power Factor Control Relay BLR-CM
Mikroprocessor controlled power factor controller with 1-phase measurement system and display of measurement values

zoom | - Full-automatic c/k-value setting, self adapting (not possible for dynamic steps), connection of different capacitor step sizes possible
- Automatic detection and usage of the optimum capacitor step
- Manual mode possible
- Multiple connection types possible through adjustable phase compensation angle
- Capable for 4-quadrant operating
- Individually configurable discharging time allows quicker switching time
- 1-phase measurement system also suitable for non-sinusodial currents and voltages
- Graphical LCD for display of step status, measurement values and system data
- Measurement display for U, I, P, Q, S, THD U, THD I, ΔQ, F, T
- Harmonics measurement for voltage and current up to the 31. order
- Counter for active and reactive work
- Flexible alarm system with up to 15 alarms
- Programmable digital input and digital output
- Programmable alarm relay with voltfree c/o contact
- Supply voltage 115/230V, 45-65Hz, other voltages on request
- Voltage measuring 50 – 530V, 45 – 65Hz
- Current measuring 15mA – 5A, suitable for CT x/1A und x/5A
- Connecting with pluggable screw terminals
- Instrument casing for cutout 144 x 144mm, depth 49mm
- Protection class IP20 (casinge), IP50 (front)
further information, optional parts and supplies(PDF; 110kb) |
 |
Power Factor Control Relay BLR-CM 3-phase
Microprocessor controlled power factor controlled with 3-phase measurement system and display of measurement values

zoom | - Full-automatic c/k-value setting, self adapting, connection of different capacitor step sizes possible
- Capacitors and detected or programmed with values in all three phases. This allows using single-phase or three-phase capacitors in any sequence
- Automatic detection and usage of the optimum capacitor step
- Manual mode possible
- multiple connecting types possible through adjustable phase compensation angle
- Capable for 4-quadrant operation
- Individually configurable discharging time allows quicker switching time
- 3-phase measurement system also suitable for non-sinusodial currents and voltages
- Graphical LCD for display of step status, measurement values and system data
- Measurement display for U, I, P, Q, S, THD U, THD I, ΔQ, F, T
- Harmonic measurement for voltage and current up to the 31. order
- Counter for active and reactive work
- Flexible alarm system with up to 15 alarms
- Programmable digital input and digital output
- Programmable alarm relay with voltfree c/o contact
- Supply voltage 115/230V, 45-65Hz, andere Spannungen auf Anfrage
- Voltage measuring 50 – 530V, 45 – 65Hz
- Current measuring 3 x 15mA – 5A, suitable for CT x/1A und x/5A
- Connection with pluggable screw terminials
- Instument casing for cutout 144 x 144mm, depth 49mm
- Protection class IP20 (casing), IP50 (front)
further information, opti*** and supplies(PDF; 170kb) |
thyristor-switches
Static Contactor BEL-TS
Thyristor switch for rapid switching of capacitors in LV-grid

zoom | - Switching without inrush current, ***ooth disconnecting
- Rapid switching
- Can be used in chocked capacitor banks and unchocked as well
- Depending on the type for max. voltage 525V or 690V
- Recovery time 20ms
- Voltage level trigger signal 8 - 30V DC
- Protection class IP00