企业资质

希而科贸易(上海)有限公司

普通会员16
|
企业等级:普通会员
经营模式:生产加工
所在地区:上海 上海
联系卖家:康经理
手机号码:18721676936
公司官网:www.silkroad24.com
企业地址:上海市奉贤区奉金路469号4幢3层2435室
企业概况

上海琪航实业有限公司主要经营:机电设备、橡塑制品、金属制品、液压设备及配件、泵、管道及配件、轴承、密封件、实验室设备及配件、机械设备、环保设备、五金交电、清洁用品、办公用品、一般劳防用品、建材、木材、阀门、仪器仪表、服装、鞋帽、服装面料及辅料、箱包、皮革制品、针纺织品批发、零售,服装设计,电子商务,......

德国Gebr. Liebisch GmbH测试模块

产品编号:3600899                    更新时间:2020-08-16
价格: 来电议定
希而科贸易(上海)有限公司

希而科贸易(上海)有限公司

  • 主营业务:工控仪表.机电产品.备品备件
  • 公司官网:www.silkroad24.com
  • 公司地址:上海市奉贤区奉金路469号4幢3层2435室

联系人名片:

康经理 18721676936

联系时务必告知是在"产品网"看到的

产品详情
型号 Gebr. Liebisch 规格 Gebr. Liebisch
品牌 Gebr. Liebisch 材质 Gebr. Liebisch
名称 Gebr. Liebisch 适用范围 Gebr. Liebisch

希而科贸易(上海)有限公司-Silkroad24 GmbH中国***

联系人:张敏 (业务部销售经理)

TEL:13585754584 021-58375543-829

FAX:021-61179684

EMAIL:zm@

***:1784691511

MSN:zhangsir_goal@

希而科优势代理德国Gebr. Liebisch GmbH测试模块

产品系列:

 

Corrosion testing units - general information

 

Modern controls of quality and corrosion research need test standa*** to detect the effect of corrosion on material and products.

We know two important kinds of corrosion testing:

  • the real time test in natural conditi***
  • the accelerated laboratory test

The greatest advantage of the laboratory test in a corrosion testing chamber is, that the user gets a quick result of the corrosion of the test samples. The quick reaction is achieved by increasing the temperature and the concentration of the medium, used in the test.

 
 
Desk type 300 litre
Cabinet type 1000 litre
Chest type 1000 litre

Desk type unit

Cabinet type unit

Chest type unit

 

Liebisch corrosion testing units are designed and c***tructed especially for these tests. Most of the frequently used standa*** can be performed with these units. We would be pleased to send you information on this.

 

Standa***

Several types of test chambers are used to test samples to different corrosion conditi***. Using temperature and humidity corrosion conditi*** are created in the test chamber. By adding aggressive test solution or pollution gas the effect can be intensified.

 
 
 

The most important tests are salt spray tests, condensation water tests and pollution gas tests with high humidity. The methods are performed individually or combined. Different national and international norms and standa*** are applied.

Important standa***

Possible units

Condensation water test DIN EN ISO 6270-2 (old DIN 50017) 

 

Condensed water is generated on the test samples at a test chamber temperature of 40°C. Demineralized water is loaded into the chamber and heated for evaporating. The relative humidity is appr. 100%. Periods of high humidity can be combined with periods of ventilation or cooling down.

K400 M-SC    K400 M-TR   K1000 M-SC  K1000 M-TR  K2000 M-SC  K2500 M-TR

 
 

Salt spray test DIN EN ISO 9227 (old DIN 50021)

 

This standard describes the spraying of a salt solution in the chamber at 35°C or 50°C. Acetic acid or copper chloride can be added to the N*** solution to accelerate the reaction. The fine salt fog condenses on the test samples and initiates corrosion.A salt spray chamber according to DIN EN ISO 9227 is supplied with a minimum volume of 400 litres.

S400 M/A-SC    S400 M/A-TR  S1000 M/A-SC S1000 M/A-TR S2000 M/A-SC  S2500 M/A-TR

 
 

Pollution gas test DIN 50018 / DIN EN ISO 6988

 

This standard is a special condensation test with the addition of sulphur dioxide. It is dosed into the test chamber at the beginning of the test.The gas combines with the demineralized water to sulphurous acid.The contaminated condensate causes a chemical reaction which is similar to the acid rain.

KB 300        KBEA 300      

 
 

Alternation test e.g. VDA 621-415 or VW PV1210  

 

Different producers, associati*** and instituti*** h***e developed standa***, which combined periods of condensation climate, salt spray, drying or ventilation. The purpose is to produce real environmental stress.

SKB400 A-SC    SKB400 A-TR  SKB1000 A-SC SKB1000 A-TR SKB2000 A-SC  SKB2500 A-TR

Liebisch process systems

 
 
 

The Liebisch test chambers are defined by aletter code, which is part of the process type description.

 
 

Process system S (salt spray)

Process system K (condensed water)

Process system B (ventilation)

Using a two-component nozzle N*** test solution is sprayed in the test chamber. Humidified compressed air - using demineralized water - sucks in the test solution from a c***tant level vessel. The fine salt fog is distributed evenly in the chamber. Parts of the system:

  • indirectly heated test chamber with electronical temperature control
  • one or more two-component nozzle(s)
  • supply tank for test solution
  • c***tant level vessel for test solution supply (alternative: dosing pump)
  • humidifier system with automatic water refill

For the condensation water test demineralized water is filled in the bottom of the chamber. The bottom is heated indirectly, the water evaporates. Parts of the system:

  • indirectly heated test chamber with electronic temperature control
  • system for water refill.                 

The process system “ventilation” is used for ventilating, drying and cooling down of the test chamber and test samples. Ambient air passes through the chamber by a fan. The test room temperature decreases to ambient and the rel. humidity is reduced to ambient conditi***. The ventilation system is added to the salt spray / condensation water system. 

 

Well-defined operating systems are only ***ailable as combination with other systems or for definite unit types!

 
 

Process system W (warm air)

Process system F (humidity)

Process system G (gas)

The warm air system is used for heating and fast drying of the test chamber and samples. It operates only in combination with process system “B” (ventilation). The difference to this system is that the ambient air is heated. The temperature can be controlled up to 60°C. You need this system for special combined tests such as Nissan CCT 1 or ASTM Prohesion.

The process system “F” is used to control the rel. humidity in the test chamber. This system can only operate in combination with the systems ventilation (B) and warm air (W). You can control RH between 30% and 100% for temperature range between ambient and 50°C.

                 

The gas process system is used for automatically dosing a defined volume of pollution gas (Sulphur dioxide). To start the test individual concentrati*** of gas volume are dosed into the test chamber. This system is ***ailable only for KBG 400 / 1000

希而科贸易(上海)有限公司电话:021-57559659传真:021-57559659联系人:康经理 18721676936

地址:上海市奉贤区奉金路469号4幢3层2435室主营产品:工控仪表.机电产品.备品备件

Copyright © 2026 版权所有: 产品网店铺主体:希而科贸易(上海)有限公司

免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责。产品网对此不承担任何保证责任。