MASS-STREAM®
The trade mark MASS-STREAM® represents a thermal measurement principle for the mass flow of gases, relatively independent of pressure and temperature. Characteristics:
| ![]() |
- Mass flow measurement and control by means of the through-flow principle
- Digital model series D-6300
- Minimum flow range 0.01 ... 0.2 ln/min (Air)
- Maximum flow range 100 ... 5,000 ln/min (Air)
- Analog model series D-6200
- Minimum flow range 0.5 ... 10 ln/min (Air)
- Maximum flow range 300 ... 6,000 ln/min (Air)
- Digital model series D-6300
- Mass flow measurement and control by means of the bypass principle
- Analog model series D-5100
- Minimum flow range 0.005 ... 0.1 ln/min (Air)
- Maximum flow range 2.5 ... 50 ln/min (Air)
- Analog model series D-5100
- Both measurement principles work with no moving parts
- Compact and rugged design
- The instrument body is ***ailable in Aluminium as well as in stainless steel AISI 316L for corrosive gases
- Additional characteristics of the D-6300 and D-6200 model series
- Less sensitive to dirt
- Less sensitive to humidity
- No inlet pipe is needed
- Less sensitive to dirt
- All mass flow meters and controllers are basically calibrated on air. If other gases or gas mixtures are used our powerful software determines a conversion factor for the desired equivalent of air (please refer toFLUIDAT® on the Net).
In general mass flow measurement is very sensitive to variati*** of the shape of the flow profile.
The MASS-STREAM® flow meters are designed for a c***istent, fully developed flow profile in the metering section and they are thus less sensitive to changes of the inlet piping conditi***.
In comparable instruments, which do not c***ist of such precauti*** for these effects of inlet piping conditi***, some severe variati*** in the accuracy might occur.
MASS-STREAM®Series D-6300
Digital Through-flow Mass Flow Meters and Controllers for Gases
Mass flow meters and controllers of M+W Instruments are suitable for all kinds of applicati***, for example in industrial, chemical, medical and laboratory environments.
The new digital MASS-STREAM® series D-6300 operates on thethrough-flow measurement principle. , following the c***tant temperature anemometer principle. It is characterised by significant improvements and follows M+W Instruments’ strategy of widely standardised product ranges. These new instruments h***e IP65 protection as a standard and are operated with a digital pc-board with all functi*** for accurate flow measurement and control. They can be supplied with commonly used digital or analogue input/output signals. Along with the standard RS232, Profibus-DP, DeviceNet, Flow-Bus and ModBus-RTU are ***ailable as an option.
One key element and innovative improvement is the optionally integrated, modern, multi-functional and multi-colour display, fully IP65 compliant with operator butt*** on the instrument. With its multiple functi***, such as actual flow indication, totalisation and alarms, the new MASS-STREAM® series D-6300 offers an excellent price-performance ratio.
Mass flow controllers for flows up to 1000 ln/min (Air) are equipped with an integrated solenoid control valve of a modular c***truction. ***ailable Kv-values are: 0.066 / 0.17 / 1.0.
Our mass flow meters can also be furnished with pipe-on motor driven control valves (***ailable Kv-values: 1,1 / 2,8 / 3,4 / 4,4) which are suitable for higher flow rates for a large variety of additional applicati***. (Further special valves and combinati*** on request.)
Features:
- Useable for virtually every kind of gases
- Compact and robust design with IP65 protection
- Very good repeatability
- Low pressure drop
- Measurement without moving parts
- Less sensitive to humidity or dirt
- No inlet pipes needed
- Optional with integrated TFT display
- multi-functional: actual flow, totaliser, alarm etc.
- operator button on the instrument
- IP65 compliant
- Maintenance-free
- Body material in Aluminium or Stainless Steel
Flow capacities (based on Air)
Mass Flow Meters | Measurement range |
Model D-6310 |
| |||
Model D-6320 |
| |||
Model D-6340 |
| |||
Model D-6360 |
| |||
Model D-6370 |
| |||
Model D-6380 |
|
Mass Flow Meters | Measurement range |
Model D-6311 |
| |||
Model D-6321 |
| |||
Model D-6341 |
| |||
Model D-6361 |
| |||
Model D-6371 |
| |||
Model D-6383 |
|
Opti***
| digital D-6300 model series with integrated multi-functional TFT display and local operator butt*** in the device (IP-65 classification) | ![]() |
| Mass flow controller for higher flow rates and kv-values of 1...4.4, c***isting of a mass flow meter with a separate motor driven valve | ![]() |
| Integrated 3 ½ digit display for actual flow for analogue D-6200 and D-5100 model series (displayed max.: 1999) | ![]() |
| Integrated 8 digit counter with display including memory and reset for analogue D-6200 and D-5100 model series | ![]() |
| Integrated set point potentiometer for analogue D-6200 and D-5100 model series | ![]() |
| Inlet pipe to straighten the flow before the instrument and low-deltaP-version for D-6200 model series | ![]() |
| Mounting plate for mass flow meters and controllers with or without separate valves | ![]() |
| Plug-in power supply 230/115 Vac / 24 Vdc 300 mA, IP-40, with 1,5 m cable (optional plugs for UK- or U.S.A.) | ![]() |
| 15-pin sub-D connector | |
| Static pressure test with certificate up to max. 50 bar | |
| Further opti*** on request |
Opti***
| digital D-6300 model series with integrated multi-functional TFT display and local operator butt*** in the device (IP-65 classification) | ![]() |
| Mass flow controller for higher flow rates and kv-values of 1...4.4, c***isting of a mass flow meter with a separate motor driven valve | ![]() |
| Integrated 3 ½ digit display for actual flow for analogue D-6200 and D-5100 model series (displayed max.: 1999) | ![]() |
| Integrated 8 digit counter with display including memory and reset for analogue D-6200 and D-5100 model series | ![]() |
| Integrated set point potentiometer for analogue D-6200 and D-5100 model series | ![]() |
| Inlet pipe to straighten the flow before the instrument and low-deltaP-version for D-6200 model series | ![]() |
| Mounting plate for mass flow meters and controllers with or without separate valves | ![]() |
| Plug-in power supply 230/115 Vac / 24 Vdc 300 mA, IP-40, with 1,5 m cable (optional plugs for UK- or U.S.A.) | ![]() |
| 15-pin sub-D connector | |
| Static pressure test with certificate up to max. 50 bar | |
| Further opti*** on request |
Model Number Identification
To process all enquiries and orders with the correct instrument it is essential to forward the following specificati***:
- Type of gas
- Flow range
- Operating pressure (for controllers inlet and outlet pressure)
- Operating and ambient temperature
- Type of process connection and seals
- Power supply
- Requested output signal (for controllers input and output signal)
Actual model number identification according to the file enclosed:
![]() Model Number Identification D-6300 Model Number Identification D-6200 and D-5100 |
Example 1:
D-6230-HGB-BB-***-24-0-S-A
Model: | Mass flow meter with Ø 8mm bore |
Power supply: | 24 Vdc |
Output signal: | 4 ... 20 mA |
Process connection: | G 1/4 |
Body material: | Aluminium |
Sealing material: | Viton |
Flow rate: | 1 ... 20 ln/min |
Type of gas: | Air |
Display: | No display |
Analogue instrument with standard sensor | 24 Vdc |
Customer data for calibration:
Operating pressure: | 4 bar |
Operating temperature: | 20° C |
Example 2:
D-5111-FAA-BB-SE-99-C-S-A
Model: | Mass flow controller for ***all flow rates |
Power supply: | 15 Vdc |
Output signal: | 0 ... 5 Vdc |
Process connection: | G 1/4 |
Body material: | SS316 |
Sealing material: | EPDM |
Flow rate: | Customer specific |
Type of gas: | Customer specific |
Display: | display for flow in ln/min |
Analogue instrument with standard sensor | 15 Vdc |
Customer data for calibration:
Type of gas: | NH3 |
Flow rate: | 0,2 ... 0,3 m³n/h |
Operating inlet pressure: | 3 ... 5 bar |
Operating outlet pressure: | 1 ... 2 bar |
Operating temperature: | 15° C |
Readout Systems
M+W Instruments supplies suitable readout systems for our analogue mass flow meters and controllers. Most commonly these are offered in a compact single channel table top housing, as a DIN panel mount cassette or as multi channel versi*** in half 19" or 19" table top or rack housings.
Functi***: | Model D-15 |
Electrical data:
| ![]() |
Model D-11 | Model D-14 |
![]() | ![]() |
Model number identification: | |||||
Code | Housing | ||||
D - 11 | 1/2 19" table housing | 42 TE | |||
D - 12 | 19" table housing | 84 TE | |||
D - 13 | 1/2 19” rack | 42 TE | |||
D - 14 | 19” rack | 84 TE | |||
D - 15 | Table top cassette | 14 TE | |||
D - 16 | Panel mount cassette | 14 TE | |||
D - 19 | Others / specified | ||||
Code | Supply voltage | ||||
- 00 | 100...240 Vac | ||||
Code | Modules with blank front | 14 TE | |||
- 00 | Rear panel with power supply + protection + mains cable | ||||
- 01 | Rear panel with additional power supply and sub-D socket | ||||
- 02 | Rear panel with sub-D socket | ||||
- 03 | Rear panel blank | ||||
Code | Modules with actual flow indication | 14 TE | |||
- 10 | Rear panel with power supply + protection + mains cable | ||||
- 11 | Rear panel with additional power supply and sub-D socket | ||||
- 12 | Rear panel with sub-D socket | ||||
- 13 | Rear panel blank | ||||
Code | Modules with totalised flow indication | 14 TE | |||
- 20 | Rear panel with power supply + protection + mains cable | ||||
- 21 | Rear panel with additional power supply and sub-D socket | ||||
- 22 | Rear panel with sub-D socket | ||||
- 23 | Rear panel blank | ||||
Code | Modules with actual flow indication and control potentiometer | 14 TE | |||
- 30 | Rear panel with power supply + protection + mains cable | ||||
- 31 | Rear panel with additional power supply and sub-D socket | ||||
- 32 | Rear panel with sub-D socket | ||||
- 33 | Rear panel blank | ||||
Code | Modules with totalised flow indication and control potentiometer | 14 TE | |||
- 40 | Rear panel with power supply + protection + mains cable | ||||
- 41 | Rear panel with additional power supply and sub-D socket | ||||
- 42 | Rear panel with sub-D socket | ||||
- 43 | Rear panel blank | ||||