类型 | 排气分析仪 | 检测误差 | 0.1(%) |
工作温度 | 100(℃) | 电压 | 230(V) |
尺寸 | 100(mm) | 品牌 | Doble Lemke GmbH |
型号 | Doble Lemke GmbH |
希而科贸易(上海)有限公司-德国Silkroad24 GmbH 中国办事处
希而科贸易(上海)有限公司-德国Silkroad24 GmbH 中国办事处
联系人:张敏 (业务部销售经理)
TEL:13585754584 021-58375543-829
FAX:021-61179684
EMAIL:zm@
QQ:1784691511
MSN:zhangsir_goal@
希而科优势代理德国Doble Lemke GmbH 放电装置分析仪
产品系列:
PARTIAL DISCHARGE
PDS100
ThePartial Discharge Surveyor PDS100provides complete substation PD survey capabilites. By simply walking around the HV apparatus, sources of partial discharges and external intereference can be detected and identified. Routine RFI surveying will assist in locating partial discharge activity while the apparatus is still in service.
PD SMART
Our digital, highly advanced partial discharge measuring and diagnostic devicePD SMART is characterized by its unique compactness and its precise measurements.
LDS-6and LDS-6/UHF
For over 10 years, the digital and portable PD measuring anddiagnosis device LDS-6accompany thousands of users around the world. With the help of the various plug-in's, the LDS-6 allows also narrow-band, RIV and UHF partial discharge measurements, besides conventional PD measurements.
LDP-5
The portableDifferential LEMKE PROBE LDP-5detects and locates dangerous partial discharges in HV equipment. Due to the light-weight construction, the Lemke probe LDP-5 can be used for both on-site inspections and measurements in the laboratory.
LDA-6
The LDA-6 is used foracoustic localizationof partial discharges inside power transformers. The acoustic, multi-channel detection of partial discharges can also be combined with electrical partial discharge measurements.
LDA-5/S
ThePD detector LDA-5/Sis used for detection of the ultrasonic sound signal of PD events at a resonance frequency of 40 kHz. Depending on the type of ultrasound receiver, either partial discharges in air (corona) or in HV equipment can be recognized, as for instance in cable systems, power transformers and switchgears (incl. GIS).
PARTIAL DISCHARGE MONITORING
PD-GUARD
The PD monitoring systemPD-GUARDis especially developed for continous partial discharge monitoring of high voltage equipment, such as generators, motors, power transformers in the conventional range of frequency.
PD-GUARD/UHF
For the implementation of permantUHF partial discharge measurements, the PD monitoring system PD-GUARD/UHF is used. The PD-GUARD/UHF is especially designed for continous PD monitoring on gas-insulated switchgears (GIS) and cable systems. The decoupling of the partial discharges will be done in the UHF frequency range.
DISSIPATION & POWER FACTOR
TD-SMART
Thedigital dissipation and capacitance measuring systemTD-SMART is a high-precise, modular acqusition and analysis system for measruing the current and other key characteristics of electrical equipment, including dissipation & power factor as well as capacitance.
PROTECTION DIAGNOSTICS
F6150
TheF6150 Power System Simulatoruses state-of-the-art digital signal processing and power amplifiers to deliver a high power, lightweight instrument for all protection testing applications.
CONTINUOUS ONLINE DIAGNOSTICS
Doble Intelligent Diagnostic Device (IDD)
Application: Transformers / Circuit Breakers
Intelligent Diagnostic Devices (IDDs),a family of continuous online diagnostic devices for power system apparatus, are designed to detect incipient problems with bushings/CTs, transformers, and circuit breakers. Now you can safely manage progressive problems and efficiently schedule corrective action. There are three types of IDD instruments: Moisture, Bushings, and Dissolved Gas Analysis
Doble LCM 500
The Doble LCM500 is a wireless system for condition
monitoring of your metal oxide surge arresters (MOSAs).
The Leakage Current Monitor (LCM) system measures the
resistive component of continuous leakage current while
the MOSA is in service and will instantly give valuable data
for the assessment of the arrester condition.
Doble DOMINO
Accurate moisture and temperature datais necessary to determine the condition of electrical apparatus or its insulating liquid. However, the data by itself may not always be sufficient to identify potential problems, especially in transformer systems. Doble developed one of the first analytical techniques for measuring dissolved water in oil and the first online moisture monitor:DOMINO.
CIRCUIT BREAKER DIAGNOSTICS
Doble TDR900
TheTDR900is a state-of-the-art Circuit Breaker Test System engineered to test all types of circuit breakers. The TDR900 provides efficient and accurate performance measurements for circuit breakers. It performs timing functions for up to four breaks per phase with motion measurements.
Doble TDR100
TheTDR100 Circuit Breaker Test Systemis a simple, effective way to assess the condition of circuit breakers and switching devices. The TDR100 is a compact unit that provides quick and reliable results.
SURGE ARRESTERS MONITORING
Doble LCM 500
The Doble LCM500 is a wireless system for condition
monitoring of your metal oxide surge arresters (MOSAs).
The Leakage Current Monitor (LCM) system measures the
resistive component of continuous leakage current while
the MOSA is in service and will instantly give valuable data
for the assessment of the arrester condition.
SWEEP FREQUENCY RESPONSE ANALYSIS
DOBLE M5400
The Doble M5400 Sweep Frequency Response Analyzer is used for reliable core and winding diagnosis of your power transformer. Use the M5400 to ensure transformer performance, reduce maintenance costs and increase service life.
DOBLE M5300
The M5300 Sweep Frequency Response Analyzer performs the same functions as the M5400, but the M5300 has a built-in PC and visual display and comes with a Laptop keyboard.
INSULATION ANALYSIS
M4100
M2H MCM
OIL/MATERIALS ANALYSIS
DOMINO Moisture Sensors - Permanent-Mount Sensors
TheDOMINO sensormeasures moisture in oil in terms of ppm and relative saturation (RS), as well as temperature. It provides continuous, reliable measurement of the water content of electrical insulating liquids and other types of oils.
Determining the moisture in insulating liquids is an essential part of any comprehensive maintenance or diagnostic program.
DOMINO Ultimate Sampling System (USS)
DOMINOUSSis a portable system consisting of either a moisture-in-oil sensor or a moisture-in-gas (dewpoint) sensor, or both. Shipped in a handy carrying case, it provides a fast, convenient way to take high-quality samples.
DOBLE Materials Laboratory
TheDoble Laboratoryis fully equipped to perform a wide variety of tests on insulating materials, with more than fifty tests offered on a routine basis. The Doble Laboratory can provide answers and solutions to your problems, based on quality data from a wide scope of testing capabilities and rich experience in apparatus diagnostics.
HV TEST SYSTEMS
Automatic HV Control Unit
This control Unit is designed for fully-automatic control of high voltage test systems.
Following application areas can be served:
• fixed-frequency AC test transformer system
• variable-frequency AC resonant test system
MANUAL HV CONTROL UNIT
Doble-Lemke offers two kinds of manual HV controls for your HV test system:
- Manual Control "LDcontrol" for HV Test Systems with Regulating Transformer (fixed frequency 50/60 Hz)
Read more...
- Manual Control "LDcontrol" for HV Test Systems with Resonant Test Set (variable frequency)
Read more...
RITHERM / SAW TECHNOLOGY
TEMPERATURE MEASUREMENTLOAD OPTIMIZATION ON OVERHEAD TRANSMISSION LINES