安立MS8604A 8G频谱分析仪100hz-8.5ghz 现货供应 /郭小文 13530101607
技术指标
General |
Frequency range |
100Hz to 8.5GHz | |
put level (continuous w***e ***erage power) |
+40dBm(10W) | ||
Reference oscillator |
Frequency:10MHz Starting characteristics:≤5×0.00000001/day(option:≤2×0.00000001/day after30 min.warm-up) *After 10min.of warm-up,compared to the frequency after 24-hour warm-up Aging rate:≤2×0.00000001/day(option:≤5×0.000000001/year) *Compared to the frequency after 24-hour warm-up Temperature characteristics:5×0.00000001/day(option:3×0.00000001/day) *0to 50℃,relative to the frequency at 25℃ |
||
Spectrum anallyzer |
Frequency |
Setting range:100Hz to 8.5GHz(resolution:1Hz),0to 2GHz(:0),1.7to7.5GHz(:1-),6.5to 8.5GHz(:1+)
Preselector range:1.7to 8.5GHz (bands:1-/1+) Display accuracy:&plu***n;(display freq.×reference curacy+span×span accuracy) Span Setting range:0Hz,100Hz to 8.5GHz Accuracy: &plu***n;2.5%(span≥1kHz),&plu***n;5%(100Hz≤span<1kHz) RBW Setting range:10Hz to 3MHz(3dB),1-3serqence Accuracy:&plu***n;20% Selectivity(60/3dB);≤15:1(100kHz to 3MHz),≤12:1(10Hz to 30kHz) VBW:1Hz to 3MHz,off,1-3 seqrence Signal purity(SSB,1MHz to 4GHz): ≤-100dBc/Hz(10kHz offset,≤-115dBc/Hz(50kHz offset),≤-120dBc/Hz(100kHzoffset) |
|
Spec- trum analyzer |
Ampl- itude |
Level |
Level measuring range:***erage:***erage noiselevl to +40dBm ***erage noise level:≤-112dBm(10MHz to 8.5Ghz,RBW 10Hz,VBW 1Hz,input tting20dB) Residual rep***e:≤-75dBm(1MHz to 8.5GHz,input tting 20dB) |
Reference level |
Setting range:-80to +40dBm Accuracy:&plu***n;0.5dB(-30to +20dBm),&plu***n;0.75dB(-40to -30dBm,+20to +40dBm),&plu***n;1.5dB(-60to-40dBm) *After calibration and at freq.100Mhz,span≤2MHz,and in auto mode for inputatt ,RBW,VBW and sweep time settings RBW switching error(after calibration):&plu***n;0.3dB(RBW:≤300kHz), |
||
Frequency rep***e | &plu***n;0.5dB(100MHz to 2GHz,band:0),&plu***n;1dB(1.7to8.5GHz,bands:1-/1+) | ||
Linearity( after calibration) |
LOG:&plu***n;0.3dB(0to -20dB,RBW:≤100kHz),&plu***n;1.5dB(0to-80dB,RBW≤10kHz) LIN:&plu***n;5%(to reference level) |
||
Dynamic range |
2nd harmonics: ≤-70dBc(5to 800MHz,band:0,mixer input level:-30dBm) ≤-80dBc(800to 850MHz,band:0,mixer input level:-30dBm), ≤-90dBc(850MHz to 2.1GHz,bands:1-,mixer input level:-10dBm) Two-signal third-ouder intermodulation distortion:≤-70dBc(10to 50MHz),≤-85dBc(50MHzto 2.1GHz) *Frequency difference between two signals≥50kHz,mixer input level:-30dBm |
||
Sweep |
Sweep time Setting range:20ms to 1000s(TRACE-FREQ,data points:NORMAL),50ms to 1000s at other conditi*** Accuracy:&plu***n;10%(20ms to 200s),&plu***n;15%(200 to 1000s) Sweep mode:CONTINUOUS,SINGLE Trigger:FREE RUN,TRIGGERED Trigger source:VIDEO,LINE,EXT(&plu***n;10V),EXT(TTL) Gate mode(OFF,random sweep mode) GATE DELAY:0to 65.5ms(in 1μs steps,GATE END:INT) GATE END:INT/EXT |
||
Time domain w***eform display |
Sweep fime:50,100to 900μs(data point:NORMAL,Onemost significant digit can be set.) 1ms to 1000s(data point:NORMAL,Two most significant digits can be set) 100,200to800μs(data point:DOUBLE,One most significant digit can be set aseven number.) 1ms to 1000s(data point:DOUBLE,Two most significant digits can be set aseven number.) Delay time Pre-trigger.-time span to 0s(in 1point steps) Post trgger:0to 65.5ms(in 1μssteps) Amplitude display resolution:50μsto 49ms,10bits*0.1%of full scale) 50ms to 1000s,14bits(0.01%of full scale) |
||
Detection mode |
POS PEAK,SAMPLE,NEG PEAK | ||
Number of points |
NOUMAL:501 points,DOUBLE:1002points | ||
AM/FM demodu- lation |
Demodulated w***eform display and monitoringdemodulated audio signal with internal speaker | ||
Auxiliary inputs/ outputs |
IF output21.4MHz:-10dBm&plu***n;2dB(at top of screen,with output terminated by 50Ωteminator),BNC connector? /> Youtput:0to 0.5V&plu***n;0.1V(at range between top and bottom of screen,LOG:10dB/div,LIN:10%/div,100MHz and with output terminated by 75Ω terminator),BNC connector External trgger input Input1:max.&plu***n;10V(in 0.1V steps, rising/falling edges selectable and pulse width≥10μs),BNC connector Input2:TTL level(rising/falling edges selectable and pulse width≥10μs, )BNC connector |
||
Power meter | Frequency range | 100kHz to 5.5GHz | |
Level range | -20to +20dBm | ||
Instrumentation accuracy |
&plu***n;0.5% | ||
Zero set |
&plu***n;0.5% of full scale at most sensitive range(100μW range) |
||
Zero shift between ranges |
&plu***n;0.2% of full scale zero setting at mostsensitive range | ||
Calibration oscillator | Freq:50MHz,Output:1.00mW,Accuracy:&plu***n;1.2% | ||
Applicable power sensor |
MA4601A | ||
Others | Display | 640×400dot,9-inch EL | |
Inputs/outputs on rear panel |
Reference input:10MHz&plu***n;10Hz,2to 5Vp-p, ≥50Ω,BNC connector Reference buffer output:10MHz,2to 3Vp-p(with the output terminated by 200Ω terminator),BNC connector Separate video output:Compatible with 8-pin DIN connector |
||
External memory | One slot for can be connected | ||
S***e/recall |
Internal memory(4sets of spectrum and Tx test conditi***),can s***e/recall setting conditi*** at extemal memory(PMC) |
||
Direct plotting | Can hard-copy screen via GPIB2 | ||
External control |
GPIB1 (IEEE488.2) |
As device controlled by host,all functi*** except power swetch Controls other instruments as controller using PTA SH1,AH1,T6,L4,SR1,RL1,PP0,DC1,DT1, C0(C1,C2,C3,and C24with PTA) |
|
GPIB2 (IEEE488.1) |
Controls other instruments as controller SH1,AH1,T6,L4,SR1,RL1,PP0,DC1,DT1 ,C1,C2,C3,***,C28 |
||
I/O port |
Output port A/B:8-bit(TTL level), Input/Output port C/C:4-bit(TTL level), EXclusive port:3-bit(TTL level) Control signal:4(TTL level),+5V output:Max.50mA |
||
RS-232C (Option 02) |
Controls other instruments as controller |
||
PTA | Language |
PTL:High level languaeg interpreter based on BASIC |
|
Programming | Using external keyboard | ||
Program memory |
On PMC or FD Upload/download from/to PC |
||
Programming capacity | 900KB | ||
Operating temperature | 0°to 50℃ | ||
Power |
85to 132/170 to 250Vac,47.5 to 63Hz ,≤500VA |
||
Dimensi*** and mass | 426(W)×221.5(H)×451(D)mm,≤27kg | ||
EMC*1 |
EN55011:1991,Group1,ClassA EN50082-1:1992 |
||
Safety |
EN61010-1:1993(Installation CategoryII ,Pollution DegreeII) |
特点
·100Hz~8.5GHz
·由单一系统评估主发射机功能
·与NADC,PDC,PHS,数字MCA, G***, DCS1800(PCN), CT2, DECT,WCPE,PACS,RCR STD-39 TETRA系统及GMSK和π/4 DQPSK通用测量软件相兼容;
·高速测量(调制精度测量小于1s)
·输入共10W(内部有用于高功率测量的20dB衰减器及功率计