加工定制: | 否 | 品牌: | SICK/施克 |
型号: | S30A-4011BA | 结构类型: | 电源内藏型 |
检测方式: | 漫反射式 | 电源电压: | c(V) |
输出方式: | c | 使用环境温度: | c(℃) |
产品认证: | ETL | 用途: | c |
S30A-4011BA
| |||||||||||||||||||||||||||||||||||||||||||
Applicati*** | |||
Hazardous area protection (vertical): | |||
Access protection (vertical): | |||
Hazardous area protection (horizontal): |
Functi*** | |||
Simultaneous monitoring of two areas: | |||
Static control outputs for switching between warning fields: | - | ||
Incremental encoder inputs: | - | ||
External device monitoring: | |||
Integrated configuration memory: | |||
Reflector mark detection: | - | ||
Expanded measured data output: | - | ||
Safe device communication via EFI/SDL: |
Technical data | |||
Laser protection class: | 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) | ||
Enclosure rating: | IP 65 (EN 60529) | ||
Protection class: | II (EN 50178) | ||
Type: | Type 3 (IEC/EN 61496-3) | ||
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) | ||
Category: | Category 3 (EN ISO 13849) | ||
Performance level: | PL d (EN ISO 13849) | ||
PFHd: | 8.0 * 1E-08 | ||
TM (mission time): | 20 a | ||
Ambient operating temperature from ... to: | -10 °C ... 50 °C | ||
Dimensi*** (W x H x D): | 155 mm x 185 mm x 160 mm | ||
Weight: | 3.3 kg | ||
Scan angle: | 190 ° | ||
Protective field range: | 4 m | ||
Maximum warning field range: | 49 m | ||
Number of field sets: | 1 | ||
Resp***e time: | 60 ms, 120 ms1) | ||
Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, selectable | ||
Distance measuring range: | 49 m | ||
Number of multiple samplings: | Configurable via CDS 2 ... 16 | ||
Electrical connection: | Plug-in connection housing with screw, screw-type terminals | ||
Supply voltage: | 16.8 V DC, 24 V DC, 28.8 V DC | ||
Number of EDM inputs: | 1 | ||
Number of reset-/restart inputs: | 1 | ||
Number of safe outputs: | 2, Safety outputs (OSSD) | ||
Number of warning field outputs: | 1 | ||
Number of application diagnostic outputs: | 1 | ||
Maximum output current: | 500 mA | ||
Configuration and diagnostics interface: | RS-232 | ||
Data interface: | RS-422 |
1)Depending on basic resp***e time and multiple sampling |