西门子LME22.331C2BT燃烧控制系统中国一级代理
上海正江实业有限公司钱小姐 18939775889 QQ:2953775738
LME21.430A2BT LME21.430C2BT
LME11.330A2BT LME11.330C2BT
LME22.331A2BT LME22.331C2BT
LME21.330C2BT LME21.330A2BT
SIEMENS程控器LME11.330A2、LME11.330C2、
SIEMENS程控器LME21.233A2, LME21.233C2,
SIEMENS程控器LME21.330A2、LME21.330C2、
SIEMENS程控器LME22.232A2、LME22.232C2,
SIEMENS程控器LME22.331A2、LME22.331C2,
SIEMENS程控器LME21.430A2BT,LME21.430C2BT
LME22.331C2BT,LME11.330C2BT
LME39.100A2、LME39.400A2
LME39.100C2、LME39.400C2
LME44.256C2 LME44.256A2
LME44.057A1 LME44.057C1
LME44.057A2 LME44.057C2
LME41.051C2 LME41.052C2
LME41.053C2 LME41.054C2
LME41.071C2 LME41.091C2
LME41.092C2 LME41.056C2
LME41.057C1 LME41.057C2
西门子LME22.331C2BT燃烧控制系统中国一级代理
上海正江实业有限公司钱小姐 18939775889 QQ:2953775738
LME…燃气燃烧器控制器9.24小时连续运行后须停机一次
西门子LME22.331C2BT燃烧控制系统中国一级代理
上海正江实业有限公司钱小姐 18939775889 QQ:2953775738
火焰探测器 |
型号 |
Tw |
t1 |
TSA |
t3n |
t3 |
t4 |
t22 |
t10 |
t11 |
t12 |
用于代替 |
用于单级燃烧器的控制,最大输出120KW |
||||||||||||
离子棒 |
LME11.330C2 |
2.5 |
30 |
3 |
2 |
2 |
|
|
5 |
|
|
|
用于二级燃烧器的控制,小风量预吹扫 |
||||||||||||
离子棒或紫外线QRA(需配合AGQ3) |
LME21.130C1 |
2.5 |
7 |
3 |
2 |
2 |
8 |
|
5 |
|
|
LGB21.130A17 |
LME21.130C2 |
2.5 |
7 |
3 |
2 |
2 |
8 |
|
5 |
|
|
LGB21.130A27 |
|
|
|
|
|
|
|
|
|
|
|
|
LMG21.130B27 |
|
LME21.230C2 |
2.5 |
20 |
3 |
2 |
2 |
8 |
|
5 |
|
|
LGB21.230A27 |
|
|
|
|
|
|
|
|
|
|
|
|
LMG21.230B27 |
|
LME21.330C1 |
2.5 |
30 |
3 |
2 |
2 |
8 |
|
5 |
|
|
|
|
LME21.330C2 |
2.5 |
30 |
3 |
2 |
2 |
8 |
|
5 |
|
|
LGB21.330A27 |
|
|
|
|
|
|
|
|
|
|
|
|
LGB21.330B27 |
|
LME21.350C1 |
2.5 |
30 |
5 |
4 |
2 |
10 |
|
5 |
|
|
LGB21.350A17 |
|
LME21.350C2 |
2.5 |
30 |
5 |
4 |
2 |
10 |
|
5 |
|
|
LMG21.350A27 |
|
|
|
|
|
|
|
|
|
|
|
|
LGB21.550A27 |
|
LME21.550C2 |
2.5 |
50 |
5 |
4 |
2 |
10 |
|
5 |
|
|
,
LMG21.550B27 |
|
用于二级燃烧器的控制,大风量预吹扫 |
||||||||||||
离子棒或紫外线QRA(需配合AGQ3) |
LME22.131C2 |
2.5 |
7 |
3 |
2 |
3 |
8 |
|
3 |
12 |
12 |
LGB22.130A27 |
|
|
|
|
|
|
|
|
|
|
|
LMB22.130B27 |
|
LME22.232C2 |
2.5 |
20 |
3 |
2 |
3 |
8 |
|
3 |
16.5 |
16.5 |
LGB22.230A27 |
|
|
|
|
|
|
|
|
|
|
|
|
LMG22.230B27 |
|
LME22.233C2 |
2.5 |
20 |
3 |
2 |
3 |
8 |
|
3 |
30 |
30 |
LMG22.230B27 |
|
LME22.331C2 |
2.5 |
20 |
3 |
2 |
3 |
8 |
|
3 |
12 |
12 |
|
|
LME22.331C2 |
2.5 |
20 |
3 |
2 |
3 |
8 |
|
3 |
12 |
12 |
LGB22.330A27 |
|
用于二级燃烧器的控制 |
||||||||||||
离子棒或紫外线QRA(需配合AGQ3) |
LME23.331C2 |
,
2.5 |
30 |
3 |
2 |
3 |
8 |
|
3 |
12 |
12 |
LGB32.330A27 |
LME23.351C2 |
2.5 |
30 |
5 |
4 |
1 |
10 |
|
3 |
12 |
12 |
LGB32.350A27 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
用于大气式燃烧器的控制 |
||||||||||||
离子棒或紫外线QRA(需配合AGQ3) |
LME44.256C2 |
16 |
9 |
5 |
4 |
2 |
10 |
5 |
|
|
|
LGB41.255A27 |
LME44.057C1 |
16 |
9 |
5 |
4 |
2 |
10 |
8 |
|
|
|
LGB41.258A17 |
|
LME44.057C2 |
16 |
9 |
5 |
4 |
2 |
10 |
8 |
|
|
|
LGB41.258A27 |
2.5
火焰探测器 |
型号 |
Tw |
t1 |
TSA |
t3n |
t3 |
t4 |
t22 |
t10 |
t11 |
t12 |
用于代替 |
用于单级燃烧器的控制,最大输出120KW |
||||||||||||
离子棒 |
LME11.330A2 |
30 |
3 |
2 |
2 |
|
|
5 |
|
|
|
|
用于二级燃烧器的控制,小风量预吹扫 |
||||||||||||
离子棒或紫外线QRA(需配合AGQ3) |
LME21.130A1 |
2.5 |
7 |
3 |
2 |
2 |
8 |
|
5 |
|
|
LGB21.130A17 |
LME21.130A2 |
2.5 |
7 |
3 |
2 |
2 |
8 |
|
5 |
|
|
LGB21.130A27 |
|
|
|
|
|
|
|
|
|
|
|
|
LMG21.130B27 |
|
LME21.230A2 |
2.5 |
20 |
3 |
2 |
2 |
8 |
|
5 |
|
|
LGB21.230A27 |
|
|
|
|
|
|
|
|
|
|
|
|
LMG21.230B27 |
|
LME21.330A1 |
2.5 |
30 |
3 |
2 |
2 |
8 |
|
5 |
|
|
|
|
LME21.330A2 |
2.5 |
30 |
3 |
2 |
2 &l, t;, /TD> |
8 |
|
5 |
|
|
LGB21.330A27 |
|
|
|
|
|
|
|
|
|
|
|
|
LGB21.330B27 |
|
LME21.350A1 |
2.5 |
30 |
5 |
4 |
2 |
10 |
|
5 |
|
|
LGB21.350A17 |
|
LME21.350A2 |
2.5 |
30 |
5 |
4 |
2 |
10 |
|
5 |
|
|
LMG21.350A27 |
|
|
|
|
|
|
|
|
|
|
|
|
LGB21.550A27 |
|
LME21.550A2 |
2.5 |
50 |
5 |
4 |
2 |
10 |
|
5 |
|
|
LMG21.550B27 |
|
用于二级燃烧器的控制,大风量预吹扫 |
||||||||||||
离子棒或紫外线QRA(需配合AGQ3) |
LME22.131A2 |
2.5 |
7 |
3 |
2 |
3 |
8 |
|
3 |
12 |
12 |
LGB22.130A27 |
|
|
|
|
|
|
|
|
|
|
|
LMB22.130B27 |
|
LME22.232A2 |
2.5 |
20 |
3 |
2 |
3 |
8 |
|
3 |
16.5 |
16.5 |
LGB22.230A27 |
|
|
|
|
|
|
|
|
|
|
|
|
LMG22.230B27 |
|
LME22.233A2 |
2.5 |
20 |
3 |
2 |
3 |
8 |
|
3 |
30 |
30 |
LMG22.230B27 |
|
LME22.331A2 |
2.5 |
20 |
3 |
2 |
3 |
8 |
|
3 |
12 |
12 |
|
|
LME22.331A2 |
2.5 |
20 |
3 |
2 |
3 |
8 |
|
3 |
12 |
12 |
LGB22.330A27 |
|
用于二级燃烧器的控制 |
||||||||||||
离子棒或紫外线QRA(需配合AGQ3) |
LME23.331A2 |
2.5 |
30 |
3 |
2 |
3 |
8 |
|
3 |
12 |
12 |
LGB32.330A27 |
LME23.351A2 |
2.5 |
30 |
5 |
4 |
1 |
10 |
|
3 |
12 |
12 |
LGB32.350A27 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
用于大气式燃烧器的控制 |
||||||||||||
离子棒或紫外线QRA(需配合AGQ3) |
LME44.256A2 |
16 |
9 |
5 |
4 |
2 |
10 |
5 |
|
|
|
LGB41.255A27 |
LME44.057A1 |
16 |
9 |
5 |
4 |
2 |
10 |
8 |
|
|
|
LGB41.258A17 |
|
LME44.057A2 |
16 |
9 |
5 |
4 |
2 |
10 |
8 |
|
|
|
LGB41.258A27 |
tw 等待时间 t1 预吹扫时间 TAS 安全点火时间 t3 预点火时间 t3n 后点火时间 t4 《BV1-BV2》或《BV1-LR》间隔 t9 第二安全时间 t10 空气压力信号的检测时间 t11 风门全开时间 t12 风门全关时间
|
||
|
LME22.232A2BT LME22.233A2BT LME22.331A2BT LME11.230A2BT
LME11.330C2BT LME21.130C2BT LME21.230C2BT LME21.330C2BT
LME22.232C2BT LME22.233C2BT LME22.331C2BT LME11.230C2BT