MB-FB-4R.HO.SC
High-Density Fieldbus Power Hub, Motherboard for Honeywell C-Series
4 segments, redundant, individual modules per segment, Customized for Honeywell, C-Series, High-power trunk: Live work on devices in any hazardous area, Optimized for size and quality, low heat dissipation, For FOUNDATION Fieldbus H1
EI-0D2-10Y-10B-Y1
Intrinsically safe Ethernet Isolator
Galvanic Isolation I.S. to non-I.S. Port, 10/100 MBit/s according to IEEE 802.3/.3u, Installation in Zone 2, Ethernet in Zone 1 or Zone 0, Standard Ethernet patch or crossover cable, DIN-Rail mounted and OEM Version
DP-LBF-I1.36.*
Fieldbus Surge Protector, Cabinet Installation, Ex ia
Modular: protection module easy to replace, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Protection module replaceable, interrupting or non-interrupting, Grounding of shield direct or via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-FT-Ex1
Fieldbus Terminator, Field Installation, Ex ia
Terminator in stainless steel housing, Intrinsically safe, FISCO and flameproof enclosure (Ex d), Installation on open cable gland, Choice of threads 20 mm, Pg 13.5 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-LBF-D1.32
Fieldbus Surge Protector, Field Installation, Ex d
Surge Protector in stainless steel housing, Flameproof enclosure (Ex d) protection, Surge protection for '+' and '-' fieldbus lead, Choice of threads 20 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-LBF-I1.32
Fieldbus Surge Protector, Field Installation, Ex ia
Surge Protector in stainless steel housing, Intrinsically safe, FISCO or Entity, Surge protection for '+' and '-' fieldbus lead, Choice of threads 20 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB0.P**.A**.1.0.***.***.****
FieldBarrier Junction Box, Polyester (GRP)
4, 8 or 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB0.S**.A**.1.0.***.***.****
FieldBarrier Junction Box, Stainless Steel
4, 8 or 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB1.P14.A**.1.*.***.***.****
FieldBarrier Junction Box, Polyester (GRP)
8, 10, 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB1.S14.A**.1.*.***.***.****
FieldBarrier Junction Box, Stainless Steel
8, 10, 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.MIO.P12.*12.F.*.***.***.**00
Multi-Input/Output Junction Box, Polyester (GRP)
For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F.MIO.P12.*12.P.*.***.***.**00
Multi-Input/Output Junction Box, Polyester (GRP)
For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F.MIO.S12.*12.F.*.***.***.**00
Multi-Input/Output Junction Box, Stainless Steel
For discrete inputs and outputs, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F.MIO.S12.*12.P.*.***.***.**00
Multi-Input/Output Junction Box, Stainless Steel
For discrete inputs and outputs, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F.SP5.P**.B**.1.0.***.***.***0
Segment Protector Junction Box, Polyester (GRP)
4 ... 12 outputs Ex ic (FISCO or Entity), Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.SP5.S**.B**.1.0.***.***.***0
Segment Protector Junction Box, Stainless Steel
4 ... 12 outputs Ex ic (FISCO or Entity), Stainless steel, electropolished, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.SPE.P**.A**.1.0.***.***.****
Segment Protector Junction Box, Polyester (GRP)
Connection of Ex d certified devices, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.SPE.S**.A**.1.0.***.***.****
Segment Protector Junction Box, Stainless Steel
Connection of Ex d certified devices, Stainless steel, electropolished, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.TI0.P12.*08.F.0.***.***.**00
Temperature Multi-Input Junction Box, Polyester (GRP)
8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F.TI0.P12.*08.P.0.***.***.**00
Temperature Multi-Input Junction Box, Polyester (GRP)
8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F.TI0.S12.*08.F.0.***.***.**00
Temperature Multi-Input Junction Box, Stainless Steel
8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F.TI0.S12.*08.P.0.***.***.**00
Temperature Multi-Input Junction Box, Stainless Steel
8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F.VC0.P21.A04.*.*.***.***.*000
Valve Coupler Junction Box, Polyester (GRP)
4 valve control and 8 position feedback signals, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.VC0.S20.A04.*.*.***.***.*000
Valve Coupler Junction Box, Stainless Steel
4 valve control and 8 position feedback signals, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F2-JB-#.*
Fieldbus junction box
4 ... 8 outputs selectable, Installation in non-explosion hazardous area, Instruments in non-explosion hazardous area, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Supports FISCO and Entity
F2-JB-I#.*
Fieldbus junction box
4 ... 8 outputs Ex ia, ib, Installation in Zone 1/Div. 1, Instruments in Zone 0...1/Div. 1, Trunk and spurs intrinsically safe, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F2-SP-IC*
Fieldbus Segment Protector
Fieldbus Segment Protector, 4 ... 10 outputs Ex ic (FISCO or Entity), Advanced fault isolation at the spur, Segment Protector in Zone 2, Instruments in Zone 2 or Zone 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F2D0-FB-Ex4.*
FieldBarrier®
4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F2D0-MIO-Ex12.FF.*
Multi-Input/Output Device with Aluminum Housing
For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F2D0-MIO-Ex12.PA.*
Multi-Input/Output Device with Aluminum Housing
For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F2D0-TI-Ex8.FF.*
Temperature Multi-Input Device with Aluminum Housing
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
F2D0-TI-Ex8.PA.*
Temperature Multi-Input Device with Aluminum Housing
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
MB-FB-GTR1*
Fieldbus Power Hub, Gateway Motherboard
For 2 gateway modules, For PROFIBUS PA, Redundant configuration, Installation in Zone 2/Class I, Div. 2, Spring terminals or screw terminals selectable
MBHC-FB-4*
Compact Fieldbus Power Hub, Motherboard, Common Interface
4 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, ***allest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-4.GT*
Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules
4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics
MBHC-FB-4.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
4 segments, individual modules per segment, Customizable cable connecti*** to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, ***allest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA
MBHC-FB-4.YO*
Compact Fieldbus Power Hub, Motherboard for Yokogawa ALF111
4 segments, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, ***allest size and lowest heat dissipation, For FOUNDATION Fieldbus H1