ELS-1
Enclosure Leakage Sensor
Housing leakage sensor, for operation with FOUNDATION Fieldbus and PROFIBUS PA, Indication via LED and Advanced Diagnostics, Intrinsically safe, FISCO or Entity, For instrument or device coupler, Fits inside terminal compartment, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HCD2-FBPS-1.23.500
Fieldbus Power Hub, Compact Power Supply Module
Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HCD2-FBPS-1.500
Fieldbus Power Hub, Compact Power Supply Module
Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-DM-A
Fieldbus Power Hub, Advanced Diagnostic Module
Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-GTR-4PA
PROFIBUS Power Hub, Gateway Module
PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting
KT-MB-GT2AD.FF
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA
R-SP-E12
Segment Protector for Cabinet Installation
Segment Protector for Cabinet Installation, 12 increased safety outputs (Ex e), Short circuit current limitation per output, Segment Protector in Zone 1/Div. 2, Instruments in Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KT-MB-GT2AD.FF.IO
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA
HD2-DM-B
Fieldbus Power Hub, Basic Diagnostic Module
Basic monitoring for power supply output and health, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KFD2-BR-1.PA.1500
Basic Segment Coupler
Output: 24 ... 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting
KLD0-SAA
Voltage adjustment module
Series voltage reducing module, Removable terminals, Polarity reversal protected, Installation in cabinet on DIN mounting rail, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KLD2-FBPS-1.25.360
Fieldbus Power Supply
Output: 25 ... 27 V/360 mA, For most fieldbus applicati***, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
BP-FBPS-1.30.1
Portable Fieldbus Battery
Portable Fieldbus Battery, Adjustable output 15 ... 30 V/max.1 A , 8 hours operation at 500 mA without recharging, IP 54 - Rain and splash proof, Rugged housing for outdoor use, For FOUNDATION Fieldbus H1 and PROFIBUS PA
Digi One® IA
COM Port Converter
Selectable serial interface RS 232, RS 422 or RS 485, Switchable RS-485 terminator, DIN rail mounting, 9...30 V DC input, 10/100 Base-T Ethernet support
EI-0D2-10Y-10B
Intrinsically safe Ethernet Isolator
Galvanic Isolation I.S. to non-I.S. Port, 10/100 MBit/s according to IEEE 802.3/.3u, Installation in Zone 2, Ethernet in Zone 1 or Zone 0, Standard Ethernet patch or crossover cable, DIN-Rail mounted and OEM Version
FBTA-228-BPFB-R-8R
Compact Fieldbus Power Hub Motherboard for Invensys FBM 228
8 segments, redundant, individual modules per segment, Customized for Invensys, FBM228, High-power trunk: Live work on devices in any hazardous area, Best quality, ***allest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
FDH-1
Fieldbus Diagnostic Handheld
Fieldbus Diagnostic Handheld, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-DM-A.RO
Fieldbus Power Hub, Advanced Diagnostic Module with Relay Output
Diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-GTR-4PA.PN
PROFINET Power Hub, Gateway Module
Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics
KFD2-BR-Ex1.3PA.93
Segment Coupler 1
Output: 12.6 ... 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-***ailability terminator
KLD2-FBPS-1.12.220
Fieldbus Power Supply
Output: 12 ... 13 V/220 mA, For battery or solar-powered applicati***, For demanding environmental conditi*** , Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
KLD2-PR-1.IEC
Fieldbus Power Repeater
Output: 24 ... 26 V/400 mA, For extension of fieldbus segments, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KT-MB-DMA
Advanced Diagnostic Module, Kit for Stand-Alone Operation
Comprehensive diagnostics for the fieldbus physical layer, Module and motherboard for retrofit of any installation, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KT-SRT-FF
Starter Kit for FOUNDATION Fieldbus H1 Infrastructure
Starter Kit for FOUNDATION Fieldbus H1 Infrastructure, Complete ha***are for connection of FOUNDATION Fieldbus H1 field devices to the host system of your choice, Output: 25 ... 28 V/360 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths
KT-SRT-PA
Starter Kit for PROFIBUS PA Infrastructure
Starter Kit for PROFIBUS PA Infrastructure, Complete ha***are for connection of PROFIBUS PA field devices to a DP-Master, Output: 24 ... 26 V/400 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths
MBHC-FB-4R.YO.R
Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111
Compact redundant Fieldbus Power Hub motherboard with redundant terminals for Yokogawa ALF111 on the right-hand side
USB-FBPS-1.11.45.NI
USB Fieldbus Power Supply
USB Fieldbus Power Supply, Output: min. 11 V/45 mA, For 1...2 devices/test setups, In conjunction with NI PCMCIA-FBUS card, Permitted for Zone 2 operation, For FOUNDATION Fieldbus H1
HD2-FBPS-1.500
Fieldbus Power Hub, Power Supply Module
Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
FBTA-228-BPFB-8
Universal Fieldbus Power Hub, Motherboard for Invensys FBM 228
8 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Features for best signal quality, low heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
FBTA-228-BPFB-R-4R
Universal Fieldbus Power Hub, Motherboard for Invensys FBM 228
4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Features for best signal quality, low heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-FBPS-1.17.500
Fieldbus Power Hub, Power Supply Module
Output: 15 ... 17 V/500 mA, Voltage limitation for FISCO ic, Entity ic, also FNICO and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-FBPS-1.23.500
Fieldbus Power Hub, Power Supply Module
Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-FBPS-1.25.360
Fieldbus Power Hub, Power Supply Module
Output: 25 ... 28 V/360 mA, Universal power supply for most applicati***, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KLD2-PR-C
Fieldbus Power Repeater
Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to Entity, 70 mA supply of the field side, Improves the fieldbus signal, Extension of the tran***ission distance by means of opening a new fieldbus segment
KLD2-PR-C1
Fieldbus Power Repeater
Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to FISCO, 100 mA supply of the field side, Improves the fieldbus signal, Extension of the tran***ission distance by means of opening a new fieldbus segment