KFD2-SOT3-Ex1.LB.IO
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFD2-SOT3--Y1
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFD2-SR2-2.W.***
Standstill and Rotational Direction Monitor
2-channel signal conditioner, 24 V DC supply, PNP/push-pull, dry contacts or NAMUR inputs, Selectable frequency trip values, 2 relay contact outputs, Start-up override, Selectable mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Rated voltage: 20 ... 30 V DC
KFD2-SR2-Ex2.W.***
Standstill and Rotational Direction Monitor
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Selectable frequency trip values, 2 relay contact outputs, Start-up override, Selectable mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
KFD2-SR3-2.2S
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-STC3-Ex1
***ART Tran***itter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire ***ART tran***itter, Output 4 mA ... 20 mA, ***ART capable up to 40 kHz (-1dB), Suitable for Honeywell DE protocol, Terminals with test points
KFD2-STC5-2
***ART Tran***itter Power Supply
2-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STC5-Ex1.2O.H
***ART Tran***itter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink/current source, Terminals with test points, High field voltage 17 V DC, Up to SIL 3 acc. to IEC 61508
KFD2-STV4-Ex1-2
***ART Tran***itter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Output 0/2 V ... 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508, Rated voltage: 20 ... 35 V DC
KFD2-STV4-Ex2-1
***ART Tran***itter Power Supply
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire ***ART tran***itters, Output 0/1 V ... 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STV5-Ex1-1
***ART Tran***itter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Output 0/1 V ... 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-UT2-Ex2-1
Universal Temperature Converter
2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-VR-Ex1.12
Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 9 V, Voltage output 0 V ... 9 V, Transfer direction: to the control system
KFD2-VR-Ex1.19
Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -10 V ... 10 V, Voltage output -10 V ... 10 V, Transfer direction: to the control system
KFD2-VR-Ex1.19-Y109129
Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -10 V ... 10 V, Tran***ission frequency up to 50 kHz, Voltage output -10 V ... 10 V, Transfer direction: to the control system
KFD2-VR2-Ex1.500M
Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV ... &plu***n; 500 mV, Voltage output 0 mV ... &plu***n; 500 mV, Selectable up/downscale sensor breakage detection, Transfer direction: to the control system
KFD0-CS-Ex2.53
Current Driver
2-channel isolated barrier, DC supply (loop powered), Current input/output 0 mA ... 40 mA, Accuracy 1 %, Low voltage drop, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-CD-Ex1.32-10
Voltage Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Current input 4 mA ... 20 mA, Voltage output 0 V ... 5 V, Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-CD-Ex1.32-15
Voltage Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 10 V, Voltage output 0 V ... 10 V, Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-CD-Ex1.32-2
Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Current input 0 mA ... 20 mA, Current output 4 mA ... 20 mA, Accuracy 0.1 %, Transfer direction: to the field
KFD2-CD-Ex1.32-21
Voltage Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 10 V, Voltage output 0 V ... 5 V, Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-CD-Ex1.32-3
Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 5 V, Current output 0 mA ... 20 mA, Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-CD-Ex1.32-5
Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 5 V, Current output 4 mA ... 20 mA, Accuracy 0.1 %, Transfer direction: to the field
KFD2-CD-Ex1.32-6
Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 10 V, Current output 0 mA ... 20 mA, Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-CD-Ex1.32-8
Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 10 V, Current output 4 mA ... 20 mA, Accuracy 0.1 %, Transfer direction: to the field
KFD2-CD-Ex1.32-9
Voltage Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Current input 0 mA ... 20 mA, Voltage output 1 V ... 5 V, Accuracy 0.1 %, Transfer direction: to the field
KFD2-STV4-Ex2-2
***ART Tran***itter Power Supply
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire ***ART tran***itters, Output 0/2 V ... 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508, Rated voltage: 20 ... 35 V DC
KFD0-RSH-1
Relay Module
1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 16 V DC ... 30 V DC, non-polarized, Fail-safe relay contact output, Up to SIL 3 acc. to IEC 61508
KFD0-RSH-1-Y2
Relay Module
1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 30 V DC, non-polarized, Fail-safe relay contact output, Test pulse immunity, Up to SIL 3 acc. to IEC 61508
KFD0-SD2-Ex1.1045
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
KFD0-SD2-Ex1.1065
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 65 mA at 9.8 V DC, Up to SIL 3 acc. to IEC 61508
KFD2-CD-1.32
Current Driver
1-channel signal conditioner, 24 V DC supply (Power Rail), Current input 0 mA ... 20 mA, Current output 0 mA ... 20 mA, Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-CD2-Ex1
Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Current input 4 mA ... 20 mA, Current output 4 mA ... 20 mA, Current output up to 700 Ω load, I/P and valve positioners, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-CD2-Ex2
Current Driver
2-channel isolated barrier, 24 V DC supply (Power Rail), Current input 0 mA ... 20 mA, Current output 0 mA ... 20 mA, Current output up to 700 Ω load, I/P and valve positioners, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-SCD2-1.LK
***ART Current Driver
1-channel signal conditioner, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.05 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-SL2-Ex1
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
KFD2-SL2-Ex1.B
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC 61508
KFD2-SL2-
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.2 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
KFD2-SOT2-Ex1.LB.IO
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Rated voltage: 20 ... 30 V DC
KFD2-SOT2-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFD2-SOT2-
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Rated voltage: 20 ... 30 V DC
KFD2-SR2-2.2S
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-SR2-Ex2.2S
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFD2-ST2-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Active fault output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFD2-ST2-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFD2-ST***-Ex1
***ART Tran***itter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Output 0/4 mA ... 20 mA, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-ST***-Ex1-Y1
***ART Tran***itter Power Supply, Output Current Sink
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Output 0/4 mA ... 20 mA current sink, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Rated voltage: 20 ... 35 V DC
KFD2-ST***-Ex1.2O
***ART Tran***itter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
KFD2-ST***-Ex1.2O.H
***ART Tran***itter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Terminal blocks with test sockets, High field voltage 17.6 V DC, Up to SIL 3 acc. to IEC 61508
KFD2-ST***-Ex1.H
***ART Tran***itter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Output 0/4 mA ... 20 mA, Terminals with test points, High field voltage 17.6 V DC, Up to SIL 2 acc. to IEC 61508, Rated voltage: 20 ... 35 V DC