MBHC-FB-8R*
Compact Fieldbus Power Hub, Motherboard, Common Interface
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, ***allest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-8R.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, ***allest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-8R.RH*
Compact Fieldbus Power Hub, Motherboard, Redundant Host Terminals
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, redundant terminals, High-power trunk: Live work on devices in any hazardous area, Best quality, ***allest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
MBHC-FB-8R.YO*
Compact Fieldbus Power Hub, Motherboard for Yokogawa ALF111
8 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, ***allest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
R2-SP-IC*
Segment Protector for Cabinet Installation
4 ... 12 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2), Advanced fault isolation at the spur, Segment Protector in Zone 2/Div. 2, Instruments in Zone 2/Div. 2 or Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
R4D0-FB-IA*
FieldBarrier® for Cabinet Installation
FieldConnex® FieldBarrier®, 8 ... 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
R8D0-MIO-Ex12.FF*
Multi-Input/Output Device for Cabinet Installation
For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
R8D0-MIO-Ex12.PA*
Multi-Input/Output Device for Cabinet Installation
For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
RD0-FB-Ex4.*
FieldBarrier®
4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA
RD0-TI-Ex8.FF.*
Temperature Multi-Input Device for Cabinet Installation
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
RD0-TI-Ex8.PA.*
Temperature Multi-Input Device for Cabinet Installation
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
SCP-LBF-IA1.36.IE*
Fieldbus Surge Protector, Field Installation on Spur
Pluggable, mounts between device coupler and spur cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-AL*.***
Segment Protector Junction Box, Aluminum
Intrinsically safe (Ex ic)/non-incendive outputs, Anodized aluminum, IP67, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-CS*.***
Segment Protector Junction Box, Carbon Steel
Intrinsically safe (Ex ic)/non-incendive outputs, Carbon steel, NEMA 4, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-FB*.***
Segment Protector Junction Box, Polyester (GRP)
Intrinsically safe (Ex ic)/non-incendive outputs, Glass fiber reinforced polyester, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-PCW.***
Segment Protector Junction Box, Polycarbonate
Intrinsically safe (Ex ic)/non-incendive outputs, Impact resistant polycarbonate, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-SS*.***
Segment Protector Junction Box, Stainless Steel
Intrinsically safe (Ex ic)/non-incendive outputs, Stainless steel, brushed NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
TCP-LBF-IA1.36.IE*
Fieldbus Surge Protector, Field Installation on Trunk
Pluggable, mounts between device coupler and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
TPH-LBF-IA1.36.DE*
Fieldbus Surge Protector, Trunk Installation on Power Hub
Pluggable, mounts between Power Hub and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield direct, For FOUNDATION Fieldbus H1 and PROFIBUS PA