LMG2...系列燃气燃烧器控制器
SIEMENS程控器LMG21.230B27, SIEMENS程控器LMG21.330B27,
SIEMENS程控器LMG22.230B27, SIEMENS程控器LMG22.330B27,
SIEMENS程控器LMG22.233B27,
LMG21.230B27,LMG21.330B27,LMG22.230B27,LMG22.330B27,LMG22.233B27,
LMG21.230A27,LMG21.330A27,LMG22.230A27,LMG22.330A27,LMG22.233A27,
LMG21.230A2BT,LMG22.330B2BT
LMG21.230A2EM,LMG22.330B2EM)
火焰探测器 型号 T Min TSA max T 3nT3 T4 min T10min T11max T12max 运行期间熄火后的反应
小火风量预吹扫,无风门控制
离子棒或紫外线QRA(需配AGQ2...A27) LMG21.130B27 2.5 7 3 2 2 8 5 --- 锁定
LMG21.230B27 2.5 20 3 2 2 8 5 --- 锁定
LMG21.330B27 2.5 30 3 2 2 8 5 --- 锁定
LMG21.350B27 2.5 30 5 4 2 10 5 --- 锁定
LMG21.530B27 2.5 50 3 2 2 8 5 --- 锁定
LMG21.550B27 2.5 50 5 4 2 10 5 --- 锁定
大火风量预吹扫,风门控制
离子棒或紫外线QRA(需配AGQ2...A27) LMG22.130B272 2.5 7 3 2 3 8 3 12 锁定
LMG22.230B272 2.5 20 3 2 3 8 3 16.5 锁定
LMG22.233B272 2.5 20 3 2 3 8 3 30 锁定
LMG22.330B272 2.5 30 3 2 3 8 3 12 锁定
小火风量预吹扫,无风门控制
离子棒或紫外线QRA(需配AGQ2...A27) LMG25.230B272 2.5 30 3 2 2 8 5 --- ***多3次重起
LMG25.330B272 2.5 30 3 2 2 8 5 --- ***多3次重起
LMG25.350B272 2.5 30 5 4 2 10 5 --- ***多3次重起
大气式燃烧
离子棒或紫外线QRA(需配AGQ2...A27) LMG49.030B27 3.5 --- 3 2 0.5 0.5 --- --- 锁定
LMG49.031B27 3.5 --- 3 2 0.5 1 --- --- ***多1次重起
tw 等待时间
t1 预吹扫时间
TSA 点火安全时间
t3 预点火时间
t3n 后点火时间
t4 电磁阀1到电磁阀2的间隔时间,或电磁阀1到比例控制开始的间隔时间
t10 空气压力信号建立时间
t11 伺服马达程序打开时间
t12 伺服马达程序关闭时间
4、LOA24系列燃油燃烧器控制器
西门子(SIEMENS)程控器 SIEMENS程控器LOA24.171B27、 SIEMENS程控器LOA44.252A27
SIEMENS程控器LOA24.171B2BT
型号 工作电压 t1 t3 TA***ax t3n t3n" t4
VAC
标准型号 LOA24.171B27 220 13s 13s 10s 15s / 15s
LOA24.171B17 110 13s 13s 10s 15s / 15s
LOA24.173A27 220 13s 13s 10s 20s 2s 20s
LOA24.174A27 220 13s 13s 10s 35s 2s 35s
带远程复位 LOA26.171B27 220 13s 13s 10s 15s / 15s
LOA36.171A27 220 13s 13s 10s 15s / 15s
点活火花检测 LOA24.571C27 220 6s 6s 10s 20s / 20s
焚化系统 LOA25.173C27 220 13s 13s 10s / 2s 15s
LOA25.173C17 110 13s 13s 10s / 2s 15s
LOA28.173A27 220 13s 13s 10s / 2s 15s
TSAm:***大点火安全时间
t1:预吹扫时间
t3:预点火时间
t3n:长点火过程时间
t3n’:短点火过程时间
t4:从***到释放的内部循环时间
5、LMO..系列西门子燃油燃烧控制器
SIEMENS程控器LMO44.255C2
型号 额定电压 电磁阀数 燃烧器出力 预热器接口 工作时间 类似型号
tw t1 TSAm t3 t3n t4
LMO14.111A2 AC230V 1 <30kg/h 有 5s 16s 10s 15s 10s - LOA24.171B27
LOA26.171B27
LOA36.171A27
LMO14.111A1 AC110V 1 <30kg/h 有 5s 16s 10s 15s 10s - LOA24.171B17
LMO14.113A2 AC230V 1 <30kg/h 有 5s 16s 10s 15s 3s - LOA24.173A27
LMO24.111A2 AC230V 2 <30kg/h 有 5s 16s 10s 15s 10s 15s LOA24.171B27
LOA26.171B27
LOA36.171A27
LMO24.111A1 AC110V 2 <30kg/h 有 5s 16s 10s 15s 10s 15s LOA24.171B17
LMO24.113A2 AC230V 2 <30kg/h 有 5s 16s 10s 15s 3s 15s LOA24.173A27
LMO24.011A2 AC230V 2 <30kg/h 有 5s 6s 10s 5s 10s 15s LOA24.571C27
LMO44.255A2 AC230V 2 >30kg/h 有 5s 26s 5s 5s 25s 5s LOA44.252A27