Electrical Characteristics (TA= 25 °C unless otherwise noted)
|
Part Number |
Hold Current |
Trip Current |
Rated Voltage |
Max Current |
Typical Power |
Maximum Time To Trip |
Resistance |
Resistance |
|
|
|
I Hold (A) |
I Trip (A) |
V Max (V) |
I Max(A) |
Pd (W) |
Current (A) |
Time (sec.) |
R Min (Ω) |
R 1Max(Ω) |
|
***D010-0805 |
0.10 |
0.30 |
15.0 |
100 |
0.5 |
0.50 |
1.50 |
0.700 |
6.000 |
|
***D020-0805 |
0.20 |
0.50 |
9.0 |
100 |
0.5 |
8.00 |
0.20 |
0.400 |
3.500 |
|
***D035-0805 |
0.35 |
0.70 |
6.0 |
100 |
0.5 |
8.00 |
0.10 |
0.250 |
1.200 |
|
***D050-0805 |
0.50 |
1.00 |
6.0 |
100 |
0.5 |
8.00 |
0.10 |
0.150 |
0.850 |
|
***D050-0805 |
0.75 |
1.50 |
6.0 |
100 |
0.6 |
8.00 |
0.20 |
0.090 |
0.350 |
|
***D100-0805 |
1.00 |
2.00 |
6.0 |
100 |
0.6 |
8.00 |
0.30 |
0.060 |
0.210 |
I Hold:Hold Current. Maximum current device will not trip in 25°C still air.
I Trip:Trip Current. Minimum current at which the device will always trip in 25°C still air.
V Max:Maximum operating voltage device can withstand without damage at rated current (Imax).
I Max:Maximum fault current device can withstand without damage at rated voltage (V max).
Pd:Power dissipation when device is in the tripped state in 25°C still air environment at rated voltage.
R Min:Minimum device resistance prior to tripping at 25°C
R 1Max:Maximum device resistance is measured one hour post reflow.